Circuit breakers
Circuit breakers
Actuator
-
1 ALARM SWITCH AND 1 SHUNT TRIP(1)
-
1 AUX SWITCH AND 1 SHUNT TRIP(4)
-
1 AUX SWITCH AND 1 UNDERVOLTAGE TRIP(2)
-
1 FORM C(2)
-
1 SHUNT TRIP(11)
-
1 UNDERVOLTAGE TRIP(2)
-
2 AUX SWITCHES(2)
-
2 AUX SWITCHES AND 1 SHUNT TRIP(1)
-
2 FORM C(1)
-
A01FD62 and 48Vdc Shunt Trip Accessories(1)
-
ACTUATING SHAFT(1)
-
HANDLE(1)
-
HANDLE W/ MASKING PLATE(2)
-
N/A(166)
-
ROTARY(2)
-
ROTARY HANDLE OPERATOR(14)
-
ROTARY MECHANISM(1)
-
ROTARY OPERATOR(4)
-
S01ED60 Accessory(1)
-
S01MN6 Accessory(1)
-
S16ED60 Accessory(3)
-
selector switch(35)
-
Shunt Trip(1)
-
Varying(617)
Amperage Rating
-
100A(5)
-
1200A(1)
-
125A(5)
-
200A(3)
-
20A(1)
-
225A(1)
-
292A(1)
-
333A(1)
-
400A(3)
-
45A(1)
-
600A(1)
-
800A(2)
Conductor Size
-
14-10AWG(CU)/12-8AWG(AL)(16)
-
14-12AWG(CU)/12-10AWG(AL)(11)
-
14-6AWG(CU)/12-6AWG(AL)(12)
-
14-8AWG(CU)/12-8AWG(AL)(25)
-
2-1/0AWG(CU)/1/0-2/0AWG(AL)(2)
-
4-1/0AWG(CU)/2-1/0AWG(AL)(11)
-
8-4AWG(CU)/8-2AWG(AL)(6)
-
8-4AWG(CU/AL)(6)
-
8-6AWG(CU)/8-4AWG(AL)(16)
Connection
-
BOLT-ON(50)
-
BoltOn(1)
-
boxterminal(1)
-
Identical wire screw connections on line and load side.(213)
-
LEFT SIDE(1)
-
LINE & LOAD STANDARD (CU/AL) LUGS(40)
-
LINE&LOADSTANDARD(CU/AL)LUGS(1)
-
Line/Load lugs installed(155)
-
LOAD END STANDARD (CU/AL) LUGS(6)
-
LOW TAB(1)
-
LOWTAB(1)
-
LUGS(7)
-
N/A(586)
-
NO-LUGS(9)
-
PLUG IN/SNAP ON(2)
-
PLUG-IN(231)
-
PLUG-IN MOUNT(3)
-
punched copper bar without any lug(19)
-
REAR(1)
-
ring cable connection(4)
-
screw-type terminals(118)
-
screw-typeterminals(3)
-
Screwless terminals on the outgoing side for 1.5 to 4mm?(1)
-
SINGLE WIRE(5)
-
SNAP ON(1)
-
spring-loaded terminals(23)
-
TWO WIRES(1)
-
W/O LUGS(4)
Continuous current / rated value
-
0.5 A(1)
-
1 A(1)
-
10 A(6)
-
100 A(31)
-
110 A(5)
-
125 A(19)
-
15 A(59)
-
150 A(8)
-
175 A(4)
-
20 A(89)
-
200 A(8)
-
225 A(4)
-
25 A(23)
-
250 A(1)
-
30 A(63)
-
35 A(22)
-
40(2)
-
40 A(41)
-
45 A(22)
-
50 A(45)
-
60 A(41)
-
65 A(1)
-
70 A(29)
-
80 A(21)
-
90 A(21)
Continuous current / rated value / maximum
-
150.0A(2)
Current Rating
-
100 A(3)
-
1250 A(1)
-
15 A(2)
-
150 A(2)
-
200 A(2)
-
225 A(2)
-
30A(1)
-
35A(1)
-
400 A(1)
-
400A(1)
-
40A(2)
-
50A(1)
-
60A(2)
-
630 A(1)
-
70 A(1)
-
90A(1)
Design of the overload release
-
THERMAL-MAGNETIC(142)
Enclosure
-
Aluminum(2)
-
Indoor Type 1(1)
-
IndoorType1(1)
-
N/A(201)
-
NEMA 1, 3, 3R, 12(4)
-
NEMA 1, 3, 3R, 12, 4, 4X(10)
-
NEMA 3R, 4X, 7CD, 12(1)
-
NEMA 4, 4X(1)
-
NEMA 4/4X(1)
-
NEMA1(1)
-
NEMA3R(2)
-
Steel(9)
-
TYPE 12(2)
-
TYPE 1F(7)
-
TYPE 1S(46)
-
TYPE 3R(14)
-
TYPE 4/4X(1)
-
TYPE 4X(3)
-
TYPE1(5)
-
TYPE12(3)
-
TYPE12K(1)
-
TYPE1F(4)
-
TYPE1S(15)
-
TYPE3R(13)
-
TYPE7/9(1)
-
Varying(630)
-
Yes(1)
Environmental Conditions
-
1/12/3R(1)
-
4/4X(1)
-
40C(2)
-
80 -50 C(145)
-
INDOOR(98)
-
INDUSTRIAL(2)
-
INDUSTRIAL CORROSIVE RESISTANT(4)
-
N/A(813)
-
NEMA 1/12/3R(2)
-
NEMA 1/12/3R/4X(1)
-
NEMA 3R/4X(1)
-
OUTDOOR(14)
Frame
-
100A(2)
-
1200A(7)
-
125A(16)
-
150A(11)
-
2, 3 pole ED2, ED4, ED6, ED6 ETI, HED4, HHED6(1)
-
225A(34)
-
250A(15)
-
3VL1-3VL13(1)
-
3VL1-3VL3(5)
-
3VL1-3VL4(3)
-
3VL3(2)
-
3VL4(3)
-
3VL4-3VL6(1)
-
3VL5(1)
-
3VL7(1)
-
400A(16)
-
600A(3)
-
800-1200A(2)
-
800A(14)
-
8UC7(2)
-
BQ(4)
-
BQ, NGG 40A(1)
-
BQ;NGG100A(1)
-
BQD, CQD, NGB(1)
-
BQD, CQD, NGG, NGB(1)
-
BQD, NGB(2)
-
CG(4)
-
CG-FG(2)
-
CQD(1)
-
CQD/G-FRAME(1)
-
DG(2)
-
DG-FG(4)
-
DG-LG(4)
-
DG-MG(1)
-
DG-PG(2)
-
EB(1)
-
ED(368)
-
ED (3 pole only)(2)
-
ED, FD, JD, LD, and LMD(3)
-
ED, FD, JD, LD, SJD, SLD, LMD(2)
-
ED-LMD(1)
-
ED-SD(1)
-
ED4;ED6orHED4(1)
-
EG(5)
-
EG (3 and 4 pole only)(1)
-
EG-DG FRAME(1)
-
FD(163)
-
FG(3)
-
For FS3(2)
-
FOR USE WTH DG-FG(1)
-
G FRAME(4)
-
GG(1)
-
J(X)D2(A), J(X)D6(A), HJD6(A), HHJD6, SHJD6 (A), L(X)D6(A), HHLD6, SCD6, HLD6(A), SHLD6(A), CJD6, CLD6, SCJD6, SCLD6(3)
-
JD(95)
-
JD, LD, SJD, SLD(1)
-
JD-LD(6)
-
JD-LMD(3)
-
JD/LD(2)
-
JD/LD/LMD(6)
-
JG(8)
-
JG-LG(3)
-
JXD2(A), JXD6(A), JD6(A), SJD6(A), HJD6(A), HJXD6(A), HHJXD6, HHJD6, SHJD6(A), CJD6, SCJD6(1)
-
JXD2;JD6;JXD6;HJD6;HJXD6;HHJD6;HHJXD6;SJD6;SHJD6(2)
-
LD(47)
-
LD-LD(1)
-
LG(1)
-
LG-MG(2)
-
LMD(19)
-
LMD6, LMXD6, HLMD6, HLMXD6, MD6, MXD6. SMD6, HMD6, HMXD6, SHMD6, CMD6, SCMD6(2)
-
MD(30)
-
MD, ND, PD, RD(2)
-
MD-ND(1)
-
MD-RD(9)
-
MD/ND(2)
-
MD/ND/PD/RD(4)
-
MG(10)
-
MG-PG(1)
-
MP(125A)(57)
-
N/A(70)
-
ND(25)
-
NG(5)
-
NG-PG(4)
-
PD(9)
-
PD-RD(3)
-
PD/RD(2)
-
PG(1)
-
QJ(44)
-
QJ2, HQJ2, QJ2H, QJH2 breakers(2)
-
QJ2, QJH2, QJ2H, HQJ2 breakers(1)
-
QJH2(2)
-
QP(125A)(106)
-
QRFRAME(2)
-
RD(5)
-
SJD(16)
-
SLD(11)
-
SMD(16)
-
SND(13)
-
SPD(1)
-
VL MG breakers(1)
Frequency Rating
-
400 Hz(15)
-
50 Hz(214)
-
50/60 Hz(907)
-
60 Hz(3)
-
N/A(169)
Height
-
0 in(1)
-
0.06 in(1)
-
0.1 in(1)
-
0.394 in(1)
-
0.5 in(1)
-
0.708661417(1)
-
0.984 in(1)
-
1 in(19)
-
1.063 in(1)
-
1.2 in(4)
-
1.252 in(1)
-
1.3 in(2)
-
1.4 in(1)
-
1.7 in(2)
-
1.75 in(1)
-
1.8 in(1)
-
1.9 in(1)
-
10 in(32)
-
10.1 in(2)
-
10.2 in(4)
-
10.9 in(1)
-
106 mm(16)
-
11 in(66)
-
11.1 in(14)
-
11.2 in(9)
-
11.3 in(6)
-
11.4 in(1)
-
11.5 in(1)
-
110(10)
-
12 in(9)
-
121(55)
-
13 in(31)
-
14.3 in(2)
-
14.4 in(1)
-
14.5 in(15)
-
14.6 in(17)
-
14.7 in(3)
-
14.8 in(3)
-
140 mm(12)
-
144.0 mm(35)
-
15 in(37)
-
15.2 in(1)
-
16.8 in(2)
-
16.9 in(1)
-
17 in(2)
-
18 in(6)
-
18.4 in(1)
-
18.5 in(1)
-
18.7 in(2)
-
18.8 in(1)
-
185.5 in(1)
-
19 in(25)
-
19.1 in(5)
-
19.2 in(5)
-
19.3 in(2)
-
19.4 in(2)
-
19.5 in(3)
-
19.6 in(2)
-
19.7 in(2)
-
19.8 in(9)
-
19.9 in(1)
-
198(3)
-
2 in(29)
-
2.1 in(1)
-
2.2 in(1)
-
2.3 in(2)
-
2.362 in(1)
-
2.4 in(1)
-
2.5 in(3)
-
2.6 in(1)
-
2.7 in(2)
-
2.795 in(1)
-
2.9 in(1)
-
20 in(5)
-
20.1 in(2)
-
20.2 in(1)
-
20.3 in(2)
-
205 mm(13)
-
268 mm(3)
-
27 in(3)
-
279.5 in(2)
-
3 in(29)
-
3.1 in(1)
-
3.4 in(1)
-
3.543 in(2)
-
3.7 in(2)
-
3.819 in(18)
-
4 in(89)
-
4.1 in(1)
-
4.2 in(2)
-
4.3 in(3)
-
4.4 in(2)
-
4.5 in(1)
-
4.625 in(22)
-
4.7 in(4)
-
4.8 in(2)
-
406.5 in(1)
-
5 in(99)
-
5.1 in(1)
-
5.3 in(3)
-
5.4 in(3)
-
5.5 in(1)
-
5.51 in(9)
-
5.6 in(1)
-
5.7 in(2)
-
5.8 in(1)
-
5.9 in(3)
-
6 in(149)
-
6.2 in(1)
-
6.3 in(2)
-
6.496 in(16)
-
6.53 in(1)
-
6.6 in(1)
-
6.614 in(2)
-
6.7 in(4)
-
6.8 in(3)
-
6.9 in(3)
-
63 in(1)
-
7 in(151)
-
7.2 in(2)
-
7.25 in(1)
-
7.28 in(6)
-
7.3 in(11)
-
7.4 in(12)
-
7.5 in(2)
-
7.6 in(1)
-
7.7 in(1)
-
7.8 in(1)
-
7.9 in(1)
-
8 in(46)
-
8.1 in(2)
-
8.2 in(1)
-
8.6 in(1)
-
8.7 in(2)
-
8.8 in(3)
-
8.9 in(1)
-
9 in(4)
-
9.2 in(1)
-
9.4 in(2)
-
9.5 in(2)
-
9.6 in(3)
-
9.7 in(2)
-
9.76 in(1)
-
9.9 in(1)
-
90(42)
-
N/A(2)
-
PENDING(3)
Interrupt Rating
-
10 AIC(35)
-
100KA(13)
-
100KAIC(36)
-
10kA(70)
-
10KAIC(37)
-
14kA(96)
-
18KA(35)
-
18KAIC(133)
-
22 AIC(11)
-
22000AIC(1)
-
22KA(28)
-
22KAIC(87)
-
25 kA(3)
-
25KA(18)
-
25KAIC(169)
-
30KAIC(3)
-
35 kA(1)
-
35KA(23)
-
35KA kA(1)
-
35KAIC(50)
-
42 AIC(1)
-
42KA(16)
-
42KAIC(54)
-
5(11)
-
50KA(2)
-
50KAIC(39)
-
5kA(109)
-
65 AIC(2)
-
65KA(36)
-
65KAIC(26)
-
N/A(132)
-
TRIP UNIT ONLY(3)
-
WITH 100kA INTERRUPTION RATING(1)
-
WITH 25kA INTERRUPTION RATING(4)
-
WITH 35kA INTERRUPTION RATING(5)
-
WITH 65kA INTERRUPTION RATING(9)
Number Of Poles
-
1(322)
-
1 to 3(2)
-
1/2inBreakers(1)
-
1;2;and3(1)
-
1inBreaker(1)
-
2(520)
-
2 to 3(3)
-
2-3(3)
-
2QTDulexBreakers(1)
-
3(1353)
-
3 to 4(4)
-
4(1)
-
N/A(112)
-
QT-DulexBreakers(1)
Operating Temperature
-
(-25C -- 75C) AMBIENT TEMPERATURE(73)
-
-25 C(1)
-
0 C(2)
-
40 -20 C(1)
-
40C(571)
-
40DEGC(83)
-
40DEGC C(1)
-
50C(17)
-
60 -20 C(109)
-
60.0 -20.0 C(35)
-
75C(57)
-
HAZARDOUS(1)
-
INDOOR(32)
-
INDUSTRIAL(4)
-
N/A(157)
-
OUTDOOR(13)
Size of the circuit-breaker
-
100A(1)
-
BL(125A)(60)
-
BQ(125A)(21)
-
CQD(100A)(1)
-
QR(250A)(35)
-
S0(5)
-
S00(8)
-
S00,S0(3)
-
S2(10)
Trip Type
-
ELECTRONIC(1)
-
ELECTRONIC TRIP UNIT(6)
-
ETU10(1)
-
ETU20(1)
-
ETU330 LIG ADJUSTMENT KNOB(3)
-
ETU820 LI LCD(1)
-
FRAME ONLY(1)
-
Interchangable(2)
-
MAGNETIC ONLY MOTOR CIRCUIT PROTECTOR(2)
-
MOTOR CIRCUIT PROTECTOR(7)
-
N/A(1)
-
Sensitrip Electronic Trip(3)
-
THERMAL MAGNETIC(71)
-
THERMAL MAGNETIC TRIP UNIT(31)
-
THERMAL-MAGNETIC(254)
-
THERMALMAGNETIC(25)
-
THERMALMAGNETICTRIPUNIT(2)
-
TM(1)
-
TM210 FIXED THERMAL FIXED MAGNETIC(7)
-
TM230 FIXED THERMAL ADJUSTABLE MAGNETIC(8)
Tripping characteristic class
-
5mA(16)
-
C(1)
-
HIGH(12)
-
STANDARD(32)
-
VERYHIGH(13)
Type
-
3RV2 circuit breaker(145)
-
3VA5(15)
-
3VA51(2)
-
3VA52(1)
-
3VA6(5)
-
3VA61 3VA62(3)
-
3VA63 3VA64(2)
-
3VL3(1)
-
3VL7(1)
-
5SY Supplementary Protectors(3)
-
Aluminum body lugs(4)
-
AUX SWITCH(2)
-
AUXILIARYSWITCH(1)
-
BLH(2)
-
BQ(9)
-
BQD(2)
-
Buck-Boost(1)
-
BUSBAR END CAP(1)
-
BUSBAR WITHOUT END CAPS(2)
-
CED6(2)
-
CFD6(2)
-
CG(1)
-
CIRCUIT BREAKER ACCESSORIES(43)
-
CircuitProtection(6)
-
Communication/Test-Tools(1)
-
COMPRESSION LUG(3)
-
CONNECTION TERMINAL(2)
-
DG(9)
-
DISTRIBUTION LUG(3)
-
Duplex, Triplex, Quadplex(1)
-
ED(7)
-
ED2(10)
-
ED4(22)
-
ED6(16)
-
EG(7)
-
Enclosures(2)
-
END PLATE(1)
-
EXTERNAL ACCESSORY(133)
-
FAULT SIGNAL CONTACTS(1)
-
FD(10)
-
FD6(4)
-
Feed-Thru Enclosure With Square D(1)
-
FG(12)
-
FXD6(6)
-
GG(1)
-
HANDLEPADLOCK(1)
-
HED4(11)
-
HFD6(1)
-
HHED6(1)
-
HHJD6(1)
-
HJXD6(1)
-
HLD6(2)
-
HMXD6(2)
-
HORIZONTAL LABEL PLATE PACK(1)
-
HQFGA2(1)
-
HQJ2(1)
-
HQP(11)
-
HQPF2(2)
-
HQS(1)
-
HSJ(44)
-
INTERNAL ACCESSORY(15)
-
JD(6)
-
JD/LD(2)
-
JD6(2)
-
JG(7)
-
JLD(1)
-
JXD2(5)
-
JXD6(7)
-
LABEL PLATE PACK(1)
-
LD(3)
-
LG(2)
-
LG-MG(1)
-
LiquidCooled(2)
-
LMD(2)
-
LMD6(1)
-
LMXD6(2)
-
LXD6(4)
-
M1(2)
-
M2(2)
-
Max-Flex(7)
-
MCCB Handle Blocking Device(1)
-
MCCB Handle Ties(2)
-
MD(1)
-
MD/ND(2)
-
MD6(1)
-
Mechanical Lug(2)
-
MG(9)
-
Miniature Circuit Breaker(114)
-
Miniature Circuit Breakers IEC(5)
-
Mounting Screw Kit(2)
-
MP(2)
-
MP-AT2(3)
-
MP-ET(1)
-
MP-GAT2(1)
-
MP-GT(1)
-
MP-HT(14)
-
MP-MT(1)
-
MP-T(43)
-
MP;BL(1)
-
MP;MH(3)
-
MXD6(2)
-
ND(1)
-
ND6(2)
-
NEMA1(2)
-
NeutralKit(1)
-
NG(11)
-
NSJ(56)
-
NXD6(1)
-
Optional Mechanical Lugs(3)
-
Padlocking Device(4)
-
PD(1)
-
PD/RD(2)
-
QAF2(9)
-
QAF2N(2)
-
QAFH2(2)
-
QE(9)
-
QEH(1)
-
QFGA2(4)
-
QFGA2N(2)
-
QFGAH2(1)
-
QJ(13)
-
QJ2(54)
-
QJ2, HQJ2, QJ2H, QJH2 breakers(1)
-
QJ2H(13)
-
QJH2(17)
-
QNH(1)
-
QP(71)
-
QP;BL;BQ;BQXD(1)
-
QPF(1)
-
QPF2(11)
-
QPF2N(3)
-
QPH(25)
-
QT(2)
-
Replacement Lugs(1)
-
ReplacementLugs(1)
-
Rotary Door Mounted Operating Handles(9)
-
SCLD6(1)
-
SCND6(1)
-
SENTRON(1)
-
Sentron Molded Case Circuit Breakers(3)
-
SentronMoldedCaseCircuitBreakers(4)
-
SLD6(1)
-
SLTypeTransferSwitches(7)
-
SND6(1)
-
STTypeTransferSwitch(2)
-
Supplementary Protector(11)
-
Supplementary Protectors(1)
-
SUPPLY TERMINAL(1)
-
Terminal Blocks(1)
-
UL CLASSIFIED(1)
-
UL489 Branch Circuit Protection(2)
Voltage / between phase and Ground (GND) / rated value
-
120 V(116)
-
277 V(15)
-
347 V(120)
Voltage / between phase and phase / rated value
-
120 V(1)
-
120/208 V(2)
-
120/240 V(5)
-
120AC V(1)
-
240 V(270)
-
277 V(1)
-
600 V(39)
Voltage Rating
-
110 to 127 VAC(1)
-
110 to 240 VAC(1)
-
120 V(170)
-
120 VAC(1)
-
120/208 V(3)
-
120/240 V(15)
-
120AC V(3)
-
127 VAC//VDC(1)
-
208 to 277 VAC(1)
-
227VAC OR 125VDC(1)
-
230/400 V(2)
-
24 VAC(1)
-
24 VDC(2)
-
24-60VAC/DC(1)
-
240 V(215)
-
240 VAC(1)
-
240VAC-125VDC(1)
-
277 V(2)
-
277/480 V(5)
-
277VAC OR 120VAC OR 125VDC(1)
-
347/600 V(13)
-
400 V(3)
-
440 to 480 VAC(1)
-
480 V(171)
-
480 VAC(1)
-
480//250 VAC//VDC(2)
-
600 V(56)
-
600 VDC(1)
-
600//250 VAC//VDC(15)
-
600//500 VAC//VDC(6)
-
690(110)
-
690 V(37)
-
AC/DC(3)
-
N/A(6)
Manufacturers
Products from this Category
Showing 4169 results
Showing 4169 results



